Pediatric Cardiology > NuMED Inc. > The Bonhoeffer MULTI-TRACK™ System

The Bonhoeffer MULTI-TRACK™ System


The NuMED MULTI-TRACK™ Kit is a well established innovative system for Mitral Dilatation.
This operator friendly system has the advantages of double balloon techniques while using a simple, single guidewire approach.  The procedure times easily match those of single balloon techniques while achieving consistently higher valve areas post dilatation.  The mismatch of the round shape of a single balloon with the oval mitral orifice probably explains the better results with double balloon dilatation. (Figures A & B)

With the guidewire still in place a MULTI-TRACK™ angiographic catheter is advanced into the left atrium for the measurement of the transmitral gradient after the dilatation.  If the result is satisfactory all catheters can then be removed, otherwise balloons of different sizes could still be advanced over the wire.

* The MULTI-TRACK™ system allows to measure the transmitral gradient  even through a single venous approach. This is obtained by gliding  two  MULTI-TRACK™ angiographic catheters along the wire which is positioned in the mitral orifice.  Therefore the arterial approach routinely used for mitral dilatation can be avoided.

Bonhoeffer MULTI-TRACK Mitral Dilatation Kit Contents
•  1 MULTI-TRACK
 balloon dilatation catheter 
   (14, 16, 18 or 20 mm in diameter)  X 5 cm in length
•  1 matched Rapid Exchange balloon dilatation catheter
•  1 14F, 70cm Dilator
•  1 MULTI-TRACK
 angiographic catheter (5F X 80 cm)
•  1 Super Stiff, preformed 0.035" guidewire

Each kit is packaged in a 120 cm long box and all catheters are individually pouched thereby maintaining sterile integrity.

Balloon
Diameter(MM)

Balloon
Length
(CM)

Shaft
Size
(FR)

Usable
Length
(CM)

Guide
Wire
(Inches)

Rated
Burst
(ATM)

Part No.
included
in Kit

Catalog
Order
No.

14.0

5.0

7

80

0.035

6.0

MTK145

BMK14

14.0

5.0

7

80

0.035

6.0

REMC145

N/A

N/A

5

80

0.035

1000 PSI

MMTA0580

N/A

N/A

14

70

0.035

N/A

D1470

N/A

N/A

0

      210

0.035

N/A

J3FC-SS 
C 210-035

16.0

5.0

7

80

0.035

5.0

MTK165

BMK16

16.0

5.0

7

80

0.035

5.0

REMC165

N/A

N/A

5

80

0.035

1000 PSI

MMTA0580

N/A

N/A

14

70

0.035

N/A

D1470

N/A

N/A

0

      210

0.035

N/A

J3FC-SS 
C 210-035

18.0

5.0

7

80

0.035

4.0

MTK185

BMK18

18.0

5.0

7

80

0.035

4.0

REMC185

N/A

N/A

5

80

0.035

1000 PSI

MMTA0580

N/A

N/A

14

70

0.035

N/A

D1470

N/A

N/A

0

      210

0.035

N/A

J3FC-SS 
C 210-035

20.0

5.0

7

80

0.035

4.0

MTK205

BMK20

20.0

5.0

7

80

0.035

4.0

REMC205

N/A

N/A

5

80

0.035

1000 PSI

MMTA0580

N/A

N/A

14

70

0.035

N/A

D1470

N/A

N/A

0

      210

0.035

N/A

J3FC-SS 
C 210-035

Scientific Literature Papers

Mitral dilatation with the Multi-Track system: an alternative approach.
Bonhoeffer P, Piechaud JF, Sidi D, Yonga G, Jowi C, Joshi M, Mugo M, Kachaner J, Parenzan L.
Cathet Cardiovasc Diagn. 1995 Oct;36(2):189-93.

Percutaneous mitral valve dilatation with the Multi-Track System.
Bonhoeffer P, Esteves C, Casal U, Tortoledo F, Yonga G, Patel T, Chisholm R, Luxereau P, Ruiz C.
Catheter Cardiovasc Interv. 1999 Oct;48(2):178-83

The multi-track angiography catheter:  a new tool for complex catheterization in congenital heart disease.
Bonhoeffer P, Piechaud JF, Stumper O, Bonnet D, Aggoun Y, Sidi, D, Kachaner J. 
Heart 1996 Aug;76(2):173-7

Percutaneous balloon mitral valvotomy: initial experience in Nairobi using a multi-track catheter system.
Yonga GO, Bonhoeffer P, Jowi CA.
East Afr Med J. 1999 Feb;76(2):71-4.

Percutaneous transvenous mitral commissurotomy in juvenile mitral stenosis
Yonga, GO, Bonhoeffer P.
East Afr Med J. 2003 Apr;80(4):172-4.